MPPT Solar Charge Controller/Solar Regulator 12v/24v 40A (SL40)
Model: MPPT Solar Charge Controller/solar regulator 12v/24v 40A Solar charger/. Solar controller 1. MPPT built in tracker 2. Three stage charging 3. PWM technology 4. Photovoltaic Charge and Load Controller 5. CE Key feature: 1. High converting efficiency higher than 97%for minimizing energy loss 2. Solar charge controller with build-in MPPT tracker for optimizing the power transformation 3. Reversed current protection for preventing equipment damage 4. Solar charge controller with BTS(battery temperature sensor), 5. Capable of selecting different charging mode for various type of batteries 6. Capable of connecting additional DC load for wider applications 7. Three stage solar charge control system(bulk, absorption, and float mode)with temperaturecompensation 8. LED indicators display charge status in real time 9. Pulse width modulation(PWM)topology combined with a multi-stage charge control algorithm leads to superior charging and enhanced batteryperformance
MODEL | SL-40A | |
Rated Voltage | 12/24 VDC | |
Rated charge current | 40A | |
Load current | 15A, can up to 40A | |
Input voltage range | 15-55VDC | |
Max. PV open circuit array voltage | 55VDC | |
Typical idle consumption | At idle < 10mA | |
Overload protection (DC load) | 2.0*Inom>5s 1.5*Inom >20s 1.25*Inom temperature controlled | |
Bulk charge | 14.6V(default) | 29.2V(default) |
Floating charge | 13.4V(default) | 26.8V(default) |
Equalization charge | 14.0V(default) | 28.0V(default) |
Over charge disconnection | 14.8V | 29.6V |
Over charge recovery | 13.6V | 27.2V |
Over discharge disconnection | 10.8 V (default) | 21.6V(default) |
Over discharge reconnection | 12.3V | 24.6V |
Temperature compensation | -13.2mV/ | -26.4mV/ |
Lead acid battery settings | Adjustable | |
NiCad battery settings | Adjustable | |
Load control mode | 1. Low Voltage Reconnect (LVR): Adjustable 2. Low Voltage Disconnect (LVD): Automatic disconnection 3. Reconnection: Includes warning flash before disconnect and reconnection | |
Low voltage reconnect | 12.0-14.0 Vdc | 24.0-28.0 Vdc |
Low voltage disconnect | 10.5-12.5 Vdc | 21.0-25.0 Vdc |
Ambient temperature | 0-40(full load) 4060(de-rating) | |
Altitude | Operating 5000 m, Non-Operating 16000 m | |
Protection class | IP21 | |
Battery temperature sensor | BTS - optional remote battery temperature sensor for increased charging precision | |
Terminal size | #8 AWG |
MPPT Solar Charge Controller/Solar Regulator 12v/24v 40A (SL40)